Commissioning-Specific Best Practices during the Construction Phase
Staying
abreast of project updates and developing a rapport with all the parties
involved in the project are important aspects of the commissioning process.
Interestingly, there is a handful of best practices that the best commissioning management
company in the UK can integrate into each stage of the commissioning
process to make it more effective. Keep reading to know about such practices that
you can use during the important phase of construction.
Conducting a Great Initial Meeting
When
conducted appropriately, the initial meeting should make the project team feel quite
confident that the commissioning management firm is available at all times to ensure the project completes
successfully. In addition to offering support to the team, best practices for
the initial meeting include the following:
* Scheduling the meeting mindfully. It
should not be scheduled too early. The reason is, that contractors may forget about
the commissioning process if too much time passes by. Whereas, if you conduct
it after equipment installation, you would miss crucial opportunities to assess
submittals and inform the process. The right time is when contractors are available
on site and the construction phase has just started, but the equipment is yet to be
installed.
* It may appear obvious, but the initial
meeting must include a complete review of the commissioning authority process. Present
a master list of equipment that requires commissioning, testing duration and
prerequisites, along with pre-functional checklists, so that each member of the
team properly understands what they should expect along the way.
* Maintaining the momentum of the
meeting is important. This can be done by visiting the site soon after the
meeting and interacting with contractors while showing interest in their work to
understand the project in a better way through keen observation.
Completing Pre-Functional Checklists by the Commissioning Authority
Instead of
depending on installation contractors, the commissioning authority should take the
responsibility to complete the documentation of the pre-functional checklist. While
acting as the most effective supporter of the project owner, the commission
authority can check appropriate installation early on in order to prevent
systemic problems from occurring in the first place.
Becoming Part of the Solution
Project teams
admire commissioning management companies that work beyond generating lists of problems.
That is to say, the commission authority should put in efforts to be part of
the solution. The commissioning deficiencies log is certainly a crucial communication
tool to track deficiencies that cannot be fixed immediately. Every deficiency
is assigned to a suitable member of the project team. This log should define every
deficiency with clarity while offering suggestions on how to resolve the issue.
When
completing the pre-functional checklist on-site, the commissioning authority should
try its best to build rapport with the members of the project team, who have
the responsibility to install equipment. When a deficiency is identified, this
will help the commissioning authority know who they should contact to in order
to discuss the deficiency – either to resolve it right away or to offer recommendations
for faster resolution.
Customising Functional Performance Testing
After the
approval of submittals, Functional Performance Testing (FPT) documentation must
be completed. The documentation should describe any particular installation or operational
requirements from the manufacturer, along with test procedures developed through
years of commissioning experience. Specific control sequences should be used
that are developed by the design team to check the response of equipment to
changes in the status, like a transition from heating to cooling or enabling the economizer
mode.
Does the
equipment set back when set points are attained? Does the equipment for backup
power work in the event of an emergency power failure? Is the direct digital
controls interface working perfectly, without errors? Such questions can easily
be addressed if the commissioning authority possesses comprehensive FPT
documentation, uses test procedures in an organised manner and records the outcomes so that testing can be done again during re-commissioning in future.
Comments